+(91)-9604149072

info@alproequipments.com

Coating Pan

Description:

Coating Pan

1) PAN: SS 304 semi ellipsoidal size pan with a circular mouth for charging & discharging of tablets Pan mounted at an inclination of 45 degrees to the horizontal.

2) DRIVE ASSEMBLY: Consists of a suitable HP 3 Phase, 440 V, 1440 RPM TEFC motor with suitable worm reduction gearbox and cone pulley arrangement to give three-speed output.

3) HOT AIR BLOWER: The unit is provided with a hot air blower consisting of suitable HP 3 Phase 440 V, 2880 RPM TEFC electric motor & centrifugal blower with damper delivering required CFM. The air is heated by means of a suitable electric heater to give air at 30 to 90 degrees Heater with thermostat control and a flexible hose pipe.

4) CONTROL PANEL: Unit provided with suitable control panel with starters and push button to actuate the drive and for blower, The circuits consist of MCCBs, relays, and contractors in series Ample overload protection is provided by the MCCB and the relay Wires coming out of the connections are numbered for easy recognition.

5) MOUNTING: The motor and gearbox is mounted inside sturdy MS frame and the pan mounted on the Gearing housing fitted in the stand. Blower mounted by the side of the stand or placed in a remote location if required.

6) FINISH: All joints argon Arc welded and all SS Parts Polished to suitable finished required of pharmaceutical equipment MS parts painted to smooth finish.

7) OPTIONS AVAILABLE : 
1. Unit with FLP motors and FLP push button station but non-FLP panel to be mounted outside FLP area, 
2. Unit in SS 316 quality contact parts, 
3. Unit with SS304 cladding / for GMP model and 
4. Steam heating for a blower.

Technical Specification

Model

CP-24”

CP-36”

CP-48”

CP-60”

CP-72"

Loading capacity

25

60 -80

100-120

150-200

250-250

Drive Motor HP 3 PH 50 C S 415 V AC line

0.50

1.00

2.00

5.00

7.5

RPM of Pan (empty)

24 / 72

12 / 36

10 / 30

8 / 24

5/10

Hot air blower motor HP 3 PH 50 C/S 415 V AC line

0.25

0.50

1.00

1.00

1.00

Blower capacity Maximum CFM

100

200

500

750

750

Heater K.W

1.5 K.W

3 K.W

4.5 K.W

6 K.W

6.K.W